flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services

Eaton A200 A200M5CAC NEMA Size 5 Non-Reversing Starter 200HP 480V 120V 60Hz / 110V 50Hz Coil

star
star
star
star
star

Size 5, Non Rev, Starter, 200HP, 600V, OLR Overload with CTs; heaters/relay per catalog

Part Number:
Warranty:
In Stock
Available
Part Number
A200M5CAC
Manufacturer
Eaton
Current Rating
270
Voltage Rating (V)
600
Number of Poles
3
Weight
29.0 lb shipping weight
Dimensions
7.59 W x 16.22 H x 7.75 D in
Standards Compliance
UL 508 (UL listed), CSA certified
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; 1NO holding circuit interlock
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
HP Rating
3-ph: 75 HP @208V, 100 HP @240V, 200 HP @480V, 200 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
5
Overload Range A
Overload with CTs; heaters/relay per catalog
Overload Class
Class 20 (Type B, manual reset)
Coil Voltage
120V 60Hz / 110V 50Hz
Enclosure Type NEMA
Open
Reversing
No
Standards Compliance
UL 508 (UL listed), CSA certified
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
Type B ambient compensated overload relay

Eaton A200 A200M5CAC NEMA Size 5 Non-Reversing Starter 200HP 480V 120V 60Hz / 110V 50Hz Coil

The Eaton A200 A200M5CAC NEMA Size 5 Non-Reversing Starter 200HP 480V 120V 60Hz / 110V 50Hz Coil is part of Eaton's A200 NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; 1NO holding circuit interlock
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
  • HP Rating: 3-ph: 75 HP @208V, 100 HP @240V, 200 HP @480V, 200 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 5
  • Overload Range A: Overload with CTs; heaters/relay per catalog
  • Overload Class: Class 20 (Type B, manual reset)
  • Coil Voltage: 120V 60Hz / 110V 50Hz
  • Enclosure Type NEMA: Open
  • Reversing: No

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.

Request a Quote