Size 8, Non Rev, Starter, 900HP, 600V, OLR Overload with CTs; heaters/relay per catalog

Part Number:
Warranty:
In Stock
Available
Part Number
A200M8CE
Manufacturer
Eaton
Current Rating
1215
Voltage Rating (V)
600
Number of Poles
3
Dimensions
37.88 W x 21.50 H x 11.75 D in
Standards Compliance
UL 508 (UL listed), CSA certified
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; 1NO holding circuit interlock
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
HP Rating
3-ph: 400 HP @208V, 450 HP @240V, 900 HP @480V, 900 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
8
Overload Range A
Overload with CTs; heaters/relay per catalog
Overload Class
Class 20 (Type B, manual reset)
Coil Voltage
600V 60Hz (rectified DC coil)
Enclosure Type NEMA
Open
Reversing
No
Standards Compliance
UL 508 (UL listed), CSA certified
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
Type B ambient compensated overload relay

Eaton A200 A200M8CE NEMA Size 8 Non-Reversing Starter 900HP 480V 600V 60Hz Coil

The Eaton A200 A200M8CE NEMA Size 8 Non-Reversing Starter 900HP 480V 600V 60Hz Coil is part of Eaton's A200 NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; 1NO holding circuit interlock
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
  • HP Rating: 3-ph: 400 HP @208V, 450 HP @240V, 900 HP @480V, 900 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 8
  • Overload Range A: Overload with CTs; heaters/relay per catalog
  • Overload Class: Class 20 (Type B, manual reset)
  • Coil Voltage: 600V 60Hz (rectified DC coil)
  • Enclosure Type NEMA: Open
  • Reversing: No

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.