flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services

Eaton A200 A210 A210M2CB NEMA Size 2 Reversing Horizontal Starter 25HP 480V 200-208V 60Hz Coil

star
star
star
star
star

Size 2, Reversing, Starter, 25HP, 600V, OLR FH heater elements ordered separately (V5-T2-136/137)

Part Number:
Warranty:
In Stock
Available
Part Number
A210M2CB
Manufacturer
Eaton
Current Rating
45
Voltage Rating (V)
600
Number of Poles
3
Weight
10.8 lb shipping weight
Dimensions
7.13 W x 7.25 H x 5.38 D in
Standards Compliance
UL 508 (UL listed), CSA certified
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; Electrically and mechanically interlocked
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
HP Rating
1-ph: 3 HP @115V, 7-1/2 HP @230V; 3-ph: 10 HP @208V, 15 HP @240V, 25 HP @480V, 25 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
2
Overload Range A
FH heater elements ordered separately (V5-T2-136/137)
Overload Class
Class 20 (Type B, manual reset)
Coil Voltage
200-208V 60Hz
Enclosure Type NEMA
Open
Reversing
Yes
Standards Compliance
UL 508 (UL listed), CSA certified
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
Type B ambient compensated overload relay

Eaton A200 A210 A210M2CB NEMA Size 2 Reversing Horizontal Starter 25HP 480V 200-208V 60Hz Coil

The Eaton A200 A210 A210M2CB NEMA Size 2 Reversing Horizontal Starter 25HP 480V 200-208V 60Hz Coil is part of Eaton's A200 A210 NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; Electrically and mechanically interlocked
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Full voltage magnetic with Type B block overload (ambient compensated, manual reset)
  • HP Rating: 1-ph: 3 HP @115V, 7-1/2 HP @230V; 3-ph: 10 HP @208V, 15 HP @240V, 25 HP @480V, 25 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 2
  • Overload Range A: FH heater elements ordered separately (V5-T2-136/137)
  • Overload Class: Class 20 (Type B, manual reset)
  • Coil Voltage: 200-208V 60Hz
  • Enclosure Type NEMA: Open
  • Reversing: Yes

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.

Request a Quote

Contact RS Breakers for pricing, availability and application support.