flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services

Eaton A200 A970 Two-Speed A970M5CB NEMA Size 5 Two-Speed One-Winding CHP Starter 200HP 480V 200-208V 60Hz Coil

star
star
star
star
star

Size 5, Non Rev, Starter, 200HP, 600V, OLR Overload with CTs; heaters/relay per catalog

Part Number:
Warranty:
In Stock
Available
Part Number
A970M5CB
Manufacturer
Eaton
Current Rating
270
Voltage Rating (V)
600
Number of Poles
3
Standards Compliance
UL 508 (UL listed), CSA certified
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; 1NO holding circuit interlock
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Two-speed, single reconnectable winding, constant horsepower
HP Rating
Constant HP: 75 HP @208V, 100 HP @240V, 200 HP @480V, 200 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
5
Overload Range A
Overload with CTs; heaters/relay per catalog
Overload Class
Class 20 (Type B, manual reset)
Coil Voltage
200-208V 60Hz
Enclosure Type NEMA
Open
Reversing
No
Standards Compliance
UL 508 (UL listed), CSA certified
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
Type B ambient compensated overload relay

Eaton A200 A970 Two-Speed A970M5CB NEMA Size 5 Two-Speed One-Winding CHP Starter 200HP 480V 200-208V 60Hz Coil

The Eaton A200 A970 Two-Speed A970M5CB NEMA Size 5 Two-Speed One-Winding CHP Starter 200HP 480V 200-208V 60Hz Coil is part of Eaton's A200 A970 Two-Speed NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; 1NO holding circuit interlock
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Two-speed, single reconnectable winding, constant horsepower
  • HP Rating: Constant HP: 75 HP @208V, 100 HP @240V, 200 HP @480V, 200 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 5
  • Overload Range A: Overload with CTs; heaters/relay per catalog
  • Overload Class: Class 20 (Type B, manual reset)
  • Coil Voltage: 200-208V 60Hz
  • Enclosure Type NEMA: Open
  • Reversing: No

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.

Request a Quote

Contact RS Breakers for pricing, availability and application support.