Size 0, Non Rev, Starter, 5HP, 600V, OLR 0.33-1.65A

Part Number:
Warranty:
In Stock
Available
Part Number
AN13BN0A5E1P6
Manufacturer
Eaton
Current Rating
18
Voltage Rating (V)
600
Number of Poles
3
Dimensions
1.77 W x 6.30 H x 5.50 D in
Standards Compliance
UL, CSA, IEC/EN 60947, VDE 0660, CE, RoHS
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; Per contactor (see Space-Savings auxiliary options)
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Full voltage magnetic with XTOE electronic overload
HP Rating
1-ph: 1 HP @115V, 2 HP @230V; 3-ph: 3 HP @208V, 3 HP @240V, 5 HP @480V, 5 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
0
Overload Range A
0.33-1.65A
Overload Class
Selectable 10A, 10, 20, 30
Coil Voltage
110V 50Hz / 120V 60Hz
Enclosure Type NEMA
Open
Reversing
No
Standards Compliance
UL, CSA, IEC/EN 60947, VDE 0660, CE, RoHS
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
XTOE electronic overload

Eaton Space-Savings AN13 AN13BN0A5E1P6 NEMA Size 0 Non-Reversing Starter XTOE 0.33-1.65A 5HP 480V 110V 50Hz / 120V 60Hz Coil

The Eaton Space-Savings AN13 AN13BN0A5E1P6 NEMA Size 0 Non-Reversing Starter XTOE 0.33-1.65A 5HP 480V 110V 50Hz / 120V 60Hz Coil is part of Eaton's Space-Savings AN13 NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; Per contactor (see Space-Savings auxiliary options)
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Full voltage magnetic with XTOE electronic overload
  • HP Rating: 1-ph: 1 HP @115V, 2 HP @230V; 3-ph: 3 HP @208V, 3 HP @240V, 5 HP @480V, 5 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 0
  • Overload Range A: 0.33-1.65A
  • Overload Class: Selectable 10A, 10, 20, 30
  • Coil Voltage: 110V 50Hz / 120V 60Hz
  • Enclosure Type NEMA: Open
  • Reversing: No

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.