flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services

Eaton Space-Savings AN13 AN13KN0TD5G100 NEMA Size 3 Non-Reversing Starter XTOE 20-100A GF 50HP 480V 24-27 Vdc Coil

star
star
star
star
star

Size 3, Non Rev, Starter, 50HP, 600V, OLR 20-100A (ground fault)

Part Number:
Warranty:
In Stock
Available
Part Number
AN13KN0TD5G100
Manufacturer
Eaton
Current Rating
90
Voltage Rating (V)
600
Number of Poles
3
Dimensions
4.40 W x 11.46 H x 6.89 D in
Standards Compliance
UL, CSA, IEC/EN 60947, VDE 0660, CE, RoHS
UL Listed
Yes
Contact Configuration and Auxiliary
3NO; Per contactor (see Space-Savings auxiliary options)
Disconnect and Short Circuit Protection
No; Not included - fuses or inverse-time breaker per NEC 430 Part D
Starter Type
Full voltage magnetic with XTOE electronic overload
HP Rating
1-ph: 7-1/2 HP @115V, 15 HP @230V; 3-ph: 25 HP @208V, 30 HP @240V, 50 HP @480V, 50 HP @600V
Voltage Rating V
600
Number of Phases
3
NEMA Size
3
Overload Range A
20-100A (ground fault)
Overload Class
Selectable 10, 20
Coil Voltage
24-27 Vdc
Enclosure Type NEMA
Open
Reversing
No
Standards Compliance
UL, CSA, IEC/EN 60947, VDE 0660, CE, RoHS
Application Use Case
Industrial motor control: pumps, fans, compressors, conveyors and machinery
Special Features
XTOE electronic overload with ground fault

Eaton Space-Savings AN13 AN13KN0TD5G100 NEMA Size 3 Non-Reversing Starter XTOE 20-100A GF 50HP 480V 24-27 Vdc Coil

The Eaton Space-Savings AN13 AN13KN0TD5G100 NEMA Size 3 Non-Reversing Starter XTOE 20-100A GF 50HP 480V 24-27 Vdc Coil is part of Eaton's Space-Savings AN13 NEMA motor control line.

Technical Specifications

  • Contact Configuration and Auxiliary: 3NO; Per contactor (see Space-Savings auxiliary options)
  • Disconnect and Short Circuit Protection: No; Not included - fuses or inverse-time breaker per NEC 430 Part D
  • Starter Type: Full voltage magnetic with XTOE electronic overload
  • HP Rating: 1-ph: 7-1/2 HP @115V, 15 HP @230V; 3-ph: 25 HP @208V, 30 HP @240V, 50 HP @480V, 50 HP @600V
  • Voltage Rating V: 600
  • Number of Phases: 3
  • NEMA Size: 3
  • Overload Range A: 20-100A (ground fault)
  • Overload Class: Selectable 10, 20
  • Coil Voltage: 24-27 Vdc
  • Enclosure Type NEMA: Open
  • Reversing: No

Applications

Ideal for pumps, fans, compressors, conveyors and general motor control in industrial plants, commercial buildings, water and wastewater facilities and OEM equipment.

Request a Quote