Square D LHL36175 175A 3-Pole 600V LH High Interrupting Circuit Breaker with Lugs

star
star
star
star
star

175A, 3-Pole, MCCB, 600V, LH-Frame, TMD

Product Code:
In Stock
Available
Part Number
LHL36175
Manufacturer
Schneider Electric
Current Rating
175A
Voltage Rating (V)
600 Vac / 250 Vdc
Number of Poles
3P
Weight
20 lbs
Dimensions
11.0 x 6.0 x 5.84 in
Standards Compliance
UL 489, CSA C22.2 No. 5.1
UL Listed
Yes
Frame Size
400A
Rated Current
175A
IC at 240V
65kAIC
IC at 480V
35kAIC
IC at 600V
25kAIC
IC at 125Vdc
50kAIC
IC at 250Vdc
50kAIC
Trip Type
Thermal-Magnetic
Trip Functions
LI (Long-Time + Instantaneous)
Magnetic Trip Range
875A - 1750A
Mounting Type
Unit Mount
Connection Type
Lugs (Line and Load)
Wire Range
(1) 1 AWG-600 kcmil or (2) 1 AWG-250 kcmil Al/Cu
Lug Kit
AL400LA
Frame Type
LH
IC Classification
High Interrupting
CSA Certified
Yes
Standards Compliance
UL 489, CSA C22.2 No. 5.1
Application Use Case
Circuit Protection
Special Features
Thermal-Magnetic, High Interrupting IC

Square D LHL36175 175A 3-Pole 600V LH High Interrupting Circuit Breaker with Lugs

400A Frame | 175A | 3P | 65kA@240V, 35kA@480V, 25kA@600V | Thermal-Magnetic

The LHL36175 is a Square D LH-frame three-pole 175-ampere molded case circuit breaker from Schneider Electric's Q4 Legacy product line. This unit mount breaker features a 400A frame with high interrupting capacity, rated for operation at 600 Vac / 250 Vdc. The breaker provides interrupting ratings of 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, and 25 kAIC at 600 Vac. DC interrupting capacity is rated at 50 kAIC at 125 Vdc and 50 kAIC at 250 Vdc. The integrated thermal-magnetic trip unit delivers LI (Long-Time and Instantaneous) overcurrent protection with an adjustable magnetic trip range from 875A to 1750A, providing flexibility for various load and coordination requirements. Configured for unit mounting with lugs (line and load), the LHL36175 is designed for direct installation in switchboards, motor control centers, and custom electrical assemblies. The unit accepts conductors in the range of (1) 1 AWG-600 kcmil or (2) 1 AWG-250 kcmil Al/Cu and has dimensions of 11.0 x 6.0 x 5.84 in at an approximate weight of 20 lbs. Manufactured in compliance with UL 489 and CSA C22.2 No. 5.1 standards, this circuit breaker delivers reliable three-phase overcurrent protection for industrial, commercial, and institutional power distribution systems. The LHL36175 is part of the Square D Q4 Legacy line, providing proven performance and broad compatibility with Square D electrical equipment and infrastructure.

Key Features

This PowerPact MCCB features Thermal-Magnetic trip protection rated 175A at 600 Vac / 250 Vdc. Frame size: 400A. Interrupting capacity: 65kA@240V, 35kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No. 5.1.