Square D PowerPact HDA26150 H-Frame 2P 150A MCCB I-Line

star
star
star
star
star

150A, 2-Pole, MCCB, 600V, 25kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HDA26150
Manufacturer
Schneider Electric
Current Rating
150A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~6 lbs
Dimensions
9.70" H x 3.00" W x 5.17" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
150A
Interrupting Capacity
25kA@240V, 18kA@480V, 14kA@600V
AIC Rating
14
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
No
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 25kA@240V, 18kA@480V, 14kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed)

Square D PowerPact HDA26150 H-Frame 2P 150A MCCB I-Line

150A Frame | 150A | 2P | 25kA@240V, 18kA@480V, 14kA@600V | Thermal-Magnetic (Fixed)

Square D's PowerPact HDA26150 H-Frame circuit breaker provides 150A 2-pole circuit protection engineered for commercial and industrial electrical distribution systems. Featuring standard interrupting capacity rated at 25kA@240V, 18kA@480V, 14kA@600V and operating at 600V AC / 250V DC, this breaker delivers proven and reliable overcurrent protection performance. Featuring a TMD (Thermal-Magnetic) trip unit, the HDA26150 delivers dependable thermal overload and magnetic short-circuit protection for continuous operation. The fixed trip characteristics are factory-calibrated for optimal protection performance, providing reliable overcurrent sensing and fast fault interruption across the full range of anticipated operating conditions. Configured for i-line plug-on installation, the HDA26150 utilizes i-line plug-on connections with I-Line Bus Connection terminations designed for reliable conductor termination. The unit accommodates 14-3/0 AWG Al/Cu conductors within compact overall dimensions of 9.70" H x 3.00" W x 5.17" D weighing ~6 lbs, optimizing installation density in electrical distribution equipment. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the HDA26150 carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 150A 2-pole overcurrent protection. The PowerPact HDA26150 represents Schneider Electric's commitment to electrical safety, performance, and reliability in power distribution equipment for professional electrical installations worldwide.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 150A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 25kA@240V, 18kA@480V, 14kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.