Square D PowerPact HGL36080T H-Frame 3P 80A Field-Interch TM

star
star
star
star
star

80A, 3-Pole, MCCB, 600V, 65kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HGL36080T
Manufacturer
Schneider Electric
Current Rating
80A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
3P
Weight
~7 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
80A
Interrupting Capacity
65kA@240V, 35kA@480V, 18kA@600V
AIC Rating
18
Trip Type
Thermal-Magnetic (Field-Interchangeable)
Trip Unit Model
TMD (Field-Interchangeable)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
No
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 65kA@240V, 35kA@480V, 18kA@600V | Poles: 3 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Field-Interchangeable) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Field-Interchangeable)

Square D PowerPact HGL36080T H-Frame 3P 80A Field-Interch TM

150A Frame | 80A | 3P | 65kA@240V, 35kA@480V, 18kA@600V | Thermal-Magnetic (Field-Interchangeable)

Engineered for demanding electrical systems, the Square D PowerPact HGL36080T is a H-Frame 80A 3-pole molded case circuit breaker with high interrupting capacity. Rated at 65kA@240V, 35kA@480V, 18kA@600V and operating at 600V AC / 250V DC, it provides reliable and consistent protection for power distribution infrastructure applications. Designed with field-interchangeable trip unit capability, this breaker allows on-site trip unit replacement without replacing the entire breaker frame, significantly reducing maintenance costs, inventory requirements, and system downtime. The TMD (Field-Interchangeable) trip unit provides reliable overcurrent protection with proven thermal overload and magnetic instantaneous response characteristics. The HGL36080T features unit mount configuration with lug (unit mount) connections and AL150HD Lug terminations for straightforward installation. Accepting 14-3/0 AWG Al/Cu conductors, this breaker measures 5.90" H x 4.50" W x 3.63" D and weighs ~7 lbs, providing a compact footprint for space-efficient installation in panelboards, switchboards, and motor control centers. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the HGL36080T carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 80A 3-pole overcurrent protection. Backed by Schneider Electric's global expertise in power distribution solutions, the HGL36080T ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Field-Interchangeable) trip protection rated 80A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 65kA@240V, 35kA@480V, 18kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.