Square D PowerPact HGL36150TU54X H-Frame 3P 150A Field-Interch Electronic
150A Frame | 150A | 3P | 65kA@240V, 35kA@480V, 18kA@600V | Electronic Field-Interch (MicroLogic 6.2E LSIG)
The Schneider Electric Square D PowerPact HGL36150TU54X is a H-Frame molded case circuit breaker rated at 150 amperes for 3-pole applications in commercial and industrial power distribution systems. This premium breaker delivers high interrupting capacity rated at 65kA@240V, 35kA@480V, 18kA@600V, operating at 600V AC for reliable overcurrent protection in critical electrical infrastructure. The HGL36150TU54X features a MicroLogic 6.2E LSIG electronic trip unit providing adjustable long-time delay, short-time delay, instantaneous, and ground fault protection settings for precise overcurrent coordination. This advanced electronic trip technology enables optimized protection curves, selective coordination with upstream and downstream protective devices, and significantly enhanced system reliability. This unit mount breaker features lug (unit mount) connections with AL150HD Lug terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 5.90" H x 4.50" W x 3.63" D and weighing ~7 lbs, the HGL36150TU54X delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the HGL36150TU54X carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 150A 3-pole overcurrent protection. Backed by Schneider Electric's global expertise in power distribution solutions, the HGL36150TU54X ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.
Key Features
This PowerPact MCCB features Electronic Field-Interch (MicroLogic 6.2E LSIG) trip protection rated 150A at 600V AC. Frame size: 150A. Interrupting capacity: 65kA@240V, 35kA@480V, 18kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.
Applications
Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.