Square D PowerPact HJA26045 H-Frame 2P 45A MCCB I-Line

star
star
star
star
star

45A, 2-Pole, MCCB, 600V, 100kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HJA26045
Manufacturer
Schneider Electric
Current Rating
45A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~6 lbs
Dimensions
9.70" H x 3.00" W x 5.17" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
45A
Interrupting Capacity
100kA@240V, 65kA@480V, 25kA@600V
AIC Rating
25
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 100kA@240V, 65kA@480V, 25kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HJA26045 H-Frame 2P 45A MCCB I-Line

150A Frame | 45A | 2P | 100kA@240V, 65kA@480V, 25kA@600V | Thermal-Magnetic (Fixed)

Square D's PowerPact HJA26045 H-Frame circuit breaker provides 45A 2-pole circuit protection engineered for commercial and industrial electrical distribution systems. Featuring extra-high interrupting capacity rated at 100kA@240V, 65kA@480V, 25kA@600V and operating at 600V AC / 250V DC, this breaker delivers proven and reliable overcurrent protection performance. The HJA26045 incorporates a TMD (Thermal-Magnetic) trip unit for reliable overcurrent protection including thermal overload and magnetic instantaneous response capabilities. This proven trip technology provides fixed protection characteristics precisely optimized for the H-Frame platform, ensuring consistent and dependable circuit protection across a wide range of operating conditions and fault scenarios. Configured for i-line plug-on installation, the HJA26045 utilizes i-line plug-on connections with I-Line Bus Connection terminations designed for reliable conductor termination. The unit accommodates 14-3/0 AWG Al/Cu conductors within compact overall dimensions of 9.70" H x 3.00" W x 5.17" D weighing ~6 lbs, optimizing installation density in electrical distribution equipment. UL 489 listed and CSA C22.2 No.5 certified, the HJA26045 meets IEC/EN 60947-2 international standards for global project specification and acceptance. Applications include feeder circuit protection, branch circuit protection, motor control center installations, panelboard and switchboard applications, and industrial power distribution systems requiring H-Frame frame-class protection capabilities. The HJA26045 exemplifies Schneider Electric's PowerPact platform engineering excellence, delivering consistent protection performance with robust construction designed for long service life in demanding environments.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 45A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 100kA@240V, 65kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.