100A, 2-Pole, MCCB, 600V, 100kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HJL26100C
Manufacturer
Schneider Electric
Current Rating
100A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~5 lbs
Dimensions
5.90" H x 3.00" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
100A
Interrupting Capacity
100kA@240V, 65kA@480V, 25kA@600V
AIC Rating
25
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 100kA@240V, 65kA@480V, 25kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HJL26100C H-Frame 2P 100A MCCB Lug 100%

150A Frame | 100A | 2P | 100kA@240V, 65kA@480V, 25kA@600V | Thermal-Magnetic (Fixed)

The PowerPact HJL26100C from Schneider Electric's Square D product line is a H-Frame 2-pole 100-amp circuit breaker designed for professional electrical installations and industrial systems. This MCCB delivers extra-high interrupting capacity of 100kA@240V, 65kA@480V, 25kA@600V at 600V AC / 250V DC for dependable overcurrent protection performance. Featuring a TMD (Thermal-Magnetic) trip unit, the HJL26100C delivers dependable thermal overload and magnetic short-circuit protection for continuous operation. The fixed trip characteristics are factory-calibrated for optimal protection performance, providing reliable overcurrent sensing and fast fault interruption across the full range of anticipated operating conditions. This unit mount breaker features lug (unit mount) connections with AL150HD Lug terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 5.90" H x 3.00" W x 3.63" D and weighing ~5 lbs, the HJL26100C delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. UL 489 listed and CSA C22.2 No.5 certified, the HJL26100C meets IEC/EN 60947-2 international standards for global project specification and acceptance. Applications include feeder circuit protection, branch circuit protection, motor control center installations, panelboard and switchboard applications, and industrial power distribution systems requiring H-Frame frame-class protection capabilities. The HJL26100C exemplifies Schneider Electric's PowerPact platform engineering excellence, delivering consistent protection performance with robust construction designed for long service life in demanding environments.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 100A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 100kA@240V, 65kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.