Square D PowerPact HJL36050C H-Frame 3P 50A MCCB Lug 100%

star
star
star
star
star

50A, 3-Pole, MCCB, 600V, 100kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HJL36050C
Manufacturer
Schneider Electric
Current Rating
50A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
3P
Weight
~7 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
50A
Interrupting Capacity
100kA@240V, 65kA@480V, 25kA@600V
AIC Rating
25
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 100kA@240V, 65kA@480V, 25kA@600V | Poles: 3 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HJL36050C H-Frame 3P 50A MCCB Lug 100%

150A Frame | 50A | 3P | 100kA@240V, 65kA@480V, 25kA@600V | Thermal-Magnetic (Fixed)

Square D's PowerPact HJL36050C H-Frame circuit breaker provides 50A 3-pole circuit protection engineered for commercial and industrial electrical distribution systems. Featuring extra-high interrupting capacity rated at 100kA@240V, 65kA@480V, 25kA@600V and operating at 600V AC / 250V DC, this breaker delivers proven and reliable overcurrent protection performance. This breaker incorporates a factory-calibrated TMD (Thermal-Magnetic) trip unit providing both thermal overload and instantaneous magnetic short-circuit protection. The H-Frame platform's proven trip mechanism ensures reliable operation with consistent and repeatable protection characteristics for dependable circuit protection throughout the breaker's entire service life. This unit mount breaker features lug (unit mount) connections with AL150HD Lug terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 5.90" H x 4.50" W x 3.63" D and weighing ~7 lbs, the HJL36050C delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. Certified to UL 489, CSA, and IEC/EN 60947-2 international standards, the HJL36050C ensures compliance across diverse global markets and jurisdictions. This breaker serves commercial and industrial power distribution, feeder protection, motor circuit applications, and switchgear installations requiring dependable H-Frame frame interrupting performance. Backed by Schneider Electric's global expertise in power distribution solutions, the HJL36050C ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 50A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 100kA@240V, 65kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.