Square D PowerPact HLA26090 H-Frame 2P 90A MCCB I-Line

star
star
star
star
star

90A, 2-Pole, MCCB, 600V, 125kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HLA26090
Manufacturer
Schneider Electric
Current Rating
90A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~6 lbs
Dimensions
9.70" H x 3.00" W x 5.17" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
90A
Interrupting Capacity
125kA@240V, 100kA@480V, 50kA@600V
AIC Rating
50
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 125kA@240V, 100kA@480V, 50kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HLA26090 H-Frame 2P 90A MCCB I-Line

150A Frame | 90A | 2P | 125kA@240V, 100kA@480V, 50kA@600V | Thermal-Magnetic (Fixed)

Schneider Electric offers the Square D PowerPact HLA26090, a premium H-Frame 2-pole molded case circuit breaker delivering 90-ampere protection for critical electrical infrastructure and power distribution. With very high interrupting capacity of 125kA@240V, 100kA@480V, 50kA@600V, this MCCB operates at 600V AC / 250V DC to provide comprehensive and dependable circuit protection. Featuring a TMD (Thermal-Magnetic) trip unit, the HLA26090 delivers dependable thermal overload and magnetic short-circuit protection for continuous operation. The fixed trip characteristics are factory-calibrated for optimal protection performance, providing reliable overcurrent sensing and fast fault interruption across the full range of anticipated operating conditions. Configured for i-line plug-on installation, the HLA26090 utilizes i-line plug-on connections with I-Line Bus Connection terminations designed for reliable conductor termination. The unit accommodates 14-3/0 AWG Al/Cu conductors within compact overall dimensions of 9.70" H x 3.00" W x 5.17" D weighing ~6 lbs, optimizing installation density in electrical distribution equipment. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the HLA26090 carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 90A 2-pole overcurrent protection. As part of the proven PowerPact family, the HLA26090 delivers dependable protection backed by Schneider Electric's extensive global engineering heritage and comprehensive industry-leading technical support resources.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 90A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 125kA@240V, 100kA@480V, 50kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.