Square D PowerPact HLA26100 H-Frame 2P 100A MCCB I-Line

star
star
star
star
star

100A, 2-Pole, MCCB, 600V, 125kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HLA26100
Manufacturer
Schneider Electric
Current Rating
100A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~6 lbs
Dimensions
9.70" H x 3.00" W x 5.17" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
100A
Interrupting Capacity
125kA@240V, 100kA@480V, 50kA@600V
AIC Rating
50
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 125kA@240V, 100kA@480V, 50kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HLA26100 H-Frame 2P 100A MCCB I-Line

150A Frame | 100A | 2P | 125kA@240V, 100kA@480V, 50kA@600V | Thermal-Magnetic (Fixed)

Engineered for demanding electrical systems, the Square D PowerPact HLA26100 is a H-Frame 100A 2-pole molded case circuit breaker with very high interrupting capacity. Rated at 125kA@240V, 100kA@480V, 50kA@600V and operating at 600V AC / 250V DC, it provides reliable and consistent protection for power distribution infrastructure applications. The HLA26100 incorporates a TMD (Thermal-Magnetic) trip unit for reliable overcurrent protection including thermal overload and magnetic instantaneous response capabilities. This proven trip technology provides fixed protection characteristics precisely optimized for the H-Frame platform, ensuring consistent and dependable circuit protection across a wide range of operating conditions and fault scenarios. This i-line plug-on breaker features i-line plug-on connections with I-Line Bus Connection terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 9.70" H x 3.00" W x 5.17" D and weighing ~6 lbs, the HLA26100 delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. Certified to UL 489, CSA, and IEC/EN 60947-2 international standards, the HLA26100 ensures compliance across diverse global markets and jurisdictions. This breaker serves commercial and industrial power distribution, feeder protection, motor circuit applications, and switchgear installations requiring dependable H-Frame frame interrupting performance. The HLA26100 exemplifies Schneider Electric's PowerPact platform engineering excellence, delivering consistent protection performance with robust construction designed for long service life in demanding environments.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 100A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 125kA@240V, 100kA@480V, 50kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.