Square D PowerPact HLL36070 H-Frame 3P 70A MCCB Lug 80%

star
star
star
star
star

70A, 3-Pole, MCCB, 600V, 125kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HLL36070
Manufacturer
Schneider Electric
Current Rating
70A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
3P
Weight
~7 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
70A
Interrupting Capacity
125kA@240V, 100kA@480V, 50kA@600V
AIC Rating
50
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 125kA@240V, 100kA@480V, 50kA@600V | Poles: 3 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HLL36070 H-Frame 3P 70A MCCB Lug 80%

150A Frame | 70A | 3P | 125kA@240V, 100kA@480V, 50kA@600V | Thermal-Magnetic (Fixed)

Schneider Electric offers the Square D PowerPact HLL36070, a premium H-Frame 3-pole molded case circuit breaker delivering 70-ampere protection for critical electrical infrastructure and power distribution. With very high interrupting capacity of 125kA@240V, 100kA@480V, 50kA@600V, this MCCB operates at 600V AC / 250V DC to provide comprehensive and dependable circuit protection. Featuring a TMD (Thermal-Magnetic) trip unit, the HLL36070 delivers dependable thermal overload and magnetic short-circuit protection for continuous operation. The fixed trip characteristics are factory-calibrated for optimal protection performance, providing reliable overcurrent sensing and fast fault interruption across the full range of anticipated operating conditions. The HLL36070 features unit mount configuration with lug (unit mount) connections and AL150HD Lug terminations for straightforward installation. Accepting 14-3/0 AWG Al/Cu conductors, this breaker measures 5.90" H x 4.50" W x 3.63" D and weighs ~7 lbs, providing a compact footprint for space-efficient installation in panelboards, switchboards, and motor control centers. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the HLL36070 carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 70A 3-pole overcurrent protection. Backed by Schneider Electric's global expertise in power distribution solutions, the HLL36070 ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 70A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 125kA@240V, 100kA@480V, 50kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.