Square D PowerPact HLL36125C H-Frame 3P 125A MCCB Lug 100%

star
star
star
star
star

125A, 3-Pole, MCCB, 600V, 125kA IC, H-Frame, TMD

Product Code:
In Stock
Available
Part Number
HLL36125C
Manufacturer
Schneider Electric
Current Rating
125A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
3P
Weight
~7 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
125A
Interrupting Capacity
125kA@240V, 100kA@480V, 50kA@600V
AIC Rating
50
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
Yes
HACR Rated
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 125kA@240V, 100kA@480V, 50kA@600V | Poles: 3 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Fixed) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Fixed), Current Limiting

Square D PowerPact HLL36125C H-Frame 3P 125A MCCB Lug 100%

150A Frame | 125A | 3P | 125kA@240V, 100kA@480V, 50kA@600V | Thermal-Magnetic (Fixed)

Engineered for demanding electrical systems, the Square D PowerPact HLL36125C is a H-Frame 125A 3-pole molded case circuit breaker with very high interrupting capacity. Rated at 125kA@240V, 100kA@480V, 50kA@600V and operating at 600V AC / 250V DC, it provides reliable and consistent protection for power distribution infrastructure applications. This breaker incorporates a factory-calibrated TMD (Thermal-Magnetic) trip unit providing both thermal overload and instantaneous magnetic short-circuit protection. The H-Frame platform's proven trip mechanism ensures reliable operation with consistent and repeatable protection characteristics for dependable circuit protection throughout the breaker's entire service life. This unit mount breaker features lug (unit mount) connections with AL150HD Lug terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 5.90" H x 4.50" W x 3.63" D and weighing ~7 lbs, the HLL36125C delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. UL 489 listed and CSA C22.2 No.5 certified, the HLL36125C meets IEC/EN 60947-2 international standards for global project specification and acceptance. Applications include feeder circuit protection, branch circuit protection, motor control center installations, panelboard and switchboard applications, and industrial power distribution systems requiring H-Frame frame-class protection capabilities. Backed by Schneider Electric's global expertise in power distribution solutions, the HLL36125C ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 125A at 600V AC / 250V DC. Frame size: 150A. Interrupting capacity: 125kA@240V, 100kA@480V, 50kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.