flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services
flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services
flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services
flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services
flash_on
100% Canadian Owned and Operated – Shipping across Canada and America – 24*7 Emergency Services

Square D PowerPact HRL36060U43X H-Frame 3P 60A Electronic MCCB 80%

star
star
star
star
star

60A, 3-Pole, MCCB, 600V, 200kA IC, H-Frame, MicroLogic 5.2A

Product Code:
In Stock
Available
Part Number
HRL36060U43X
Manufacturer
Schneider Electric
Current Rating
60A
Voltage Rating (V)
600V AC
Number of Poles
3P
Weight
~7 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
150A
Rated Current
60A
Interrupting Capacity
200kA@240V, 200kA@480V, 100kA@600V
AIC Rating
100
Trip Type
Electronic (MicroLogic 5.2A LSI)
Trip Unit Model
MicroLogic 5.2A LSI
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL150HD Lug
Current Limiting
Yes
Wire Range
14-3/0 AWG Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: H-Frame 150A | IC: 200kA@240V, 200kA@480V, 100kA@600V | Poles: 3 | Voltage: 600V AC | Trip: Electronic (MicroLogic 5.2A LSI) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Electronic (MicroLogic 5.2A LSI), Current Limiting

Square D PowerPact HRL36060U43X H-Frame 3P 60A Electronic MCCB 80%

150A Frame | 60A | 3P | 200kA@240V, 200kA@480V, 100kA@600V | Electronic (MicroLogic 5.2A LSI)

The PowerPact HRL36060U43X from Schneider Electric's Square D product line is a H-Frame 3-pole 60-amp circuit breaker designed for professional electrical installations and industrial systems. This MCCB delivers extreme interrupting capacity of 200kA@240V, 200kA@480V, 100kA@600V at 600V AC for dependable overcurrent protection performance. The HRL36060U43X features a MicroLogic 5.2A LSI electronic trip unit providing adjustable long-time delay, short-time delay, instantaneous, and ground fault protection settings for precise overcurrent coordination. This advanced electronic trip technology enables optimized protection curves, selective coordination with upstream and downstream protective devices, and significantly enhanced system reliability. This unit mount breaker features lug (unit mount) connections with AL150HD Lug terminations, accepting 14-3/0 AWG Al/Cu conductors for versatile wiring applications. With overall dimensions of 5.90" H x 4.50" W x 3.63" D and weighing ~7 lbs, the HRL36060U43X delivers H-Frame frame protection in a space-efficient package suitable for dense electrical equipment layouts. Certified to UL 489, CSA, and IEC/EN 60947-2 international standards, the HRL36060U43X ensures compliance across diverse global markets and jurisdictions. This breaker serves commercial and industrial power distribution, feeder protection, motor circuit applications, and switchgear installations requiring dependable H-Frame frame interrupting performance. As part of the proven PowerPact family, the HRL36060U43X delivers dependable protection backed by Schneider Electric's extensive global engineering heritage and comprehensive industry-leading technical support resources.

Key Features

This PowerPact MCCB features Electronic (MicroLogic 5.2A LSI) trip protection rated 60A at 600V AC. Frame size: 150A. Interrupting capacity: 200kA@240V, 200kA@480V, 100kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.