Square D PowerPact JDL36250 J-Frame 3P 250A MCCB Lug 80%

star
star
star
star
star

250A, 3-Pole, MCCB, 600V, 25kA IC, J-Frame, TMD

Product Code:
In Stock
Available
Part Number
JDL36250
Manufacturer
Schneider Electric
Current Rating
250A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
3P
Weight
~12 lbs
Dimensions
5.90" H x 4.50" W x 3.63" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
250A
Rated Current
250A
Interrupting Capacity
25kA@240V, 18kA@480V, 14kA@600V
AIC Rating
14
Trip Type
Thermal-Magnetic (Adjustable)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL175JD/AL250JD Lug
Current Limiting
No
HACR Rated
Yes
Wire Range
3/0-350 kcmil Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: J-Frame 250A | IC: 25kA@240V, 18kA@480V, 14kA@600V | Poles: 3 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Adjustable) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Adjustable)

Square D PowerPact JDL36250 J-Frame 3P 250A MCCB Lug 80%

250A Frame | 250A | 3P | 25kA@240V, 18kA@480V, 14kA@600V | Thermal-Magnetic (Adjustable)

Square D's PowerPact JDL36250 J-Frame circuit breaker provides 250A 3-pole circuit protection engineered for commercial and industrial electrical distribution systems. Featuring standard interrupting capacity rated at 25kA@240V, 18kA@480V, 14kA@600V and operating at 600V AC / 250V DC, this breaker delivers proven and reliable overcurrent protection performance. The JDL36250 incorporates a TMD (Thermal-Magnetic) trip unit for reliable overcurrent protection including thermal overload and magnetic instantaneous response capabilities. This proven trip technology provides fixed protection characteristics precisely optimized for the J-Frame platform, ensuring consistent and dependable circuit protection across a wide range of operating conditions and fault scenarios. Configured for unit mount installation, the JDL36250 utilizes lug (unit mount) connections with AL175JD/AL250JD Lug terminations designed for reliable conductor termination. The unit accommodates 3/0-350 kcmil Al/Cu conductors within compact overall dimensions of 5.90" H x 4.50" W x 3.63" D weighing ~12 lbs, optimizing installation density in electrical distribution equipment. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the JDL36250 carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 250A 3-pole overcurrent protection. Backed by Schneider Electric's global expertise in power distribution solutions, the JDL36250 ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Adjustable) trip protection rated 250A at 600V AC / 250V DC. Frame size: 250A. Interrupting capacity: 25kA@240V, 18kA@480V, 14kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.