Square D PowerPact JDL36250T J-Frame 3P 250A Field-Interch TM
250A Frame | 250A | 3P | 25kA@240V, 18kA@480V, 14kA@600V | Thermal-Magnetic (Field-Interchangeable)
The Schneider Electric Square D PowerPact JDL36250T is a J-Frame molded case circuit breaker rated at 250 amperes for 3-pole applications in commercial and industrial power distribution systems. This premium breaker delivers standard interrupting capacity rated at 25kA@240V, 18kA@480V, 14kA@600V, operating at 600V AC / 250V DC for reliable overcurrent protection in critical electrical infrastructure. Designed with field-interchangeable trip unit capability, this breaker allows on-site trip unit replacement without replacing the entire breaker frame, significantly reducing maintenance costs, inventory requirements, and system downtime. The TMD (Field-Interchangeable) trip unit provides reliable overcurrent protection with proven thermal overload and magnetic instantaneous response characteristics. The JDL36250T features unit mount configuration with lug (unit mount) connections and AL250JD Lug terminations for straightforward installation. Accepting 3/0-350 kcmil Al/Cu conductors, this breaker measures 5.90" H x 4.50" W x 3.63" D and weighs ~12 lbs, providing a compact footprint for space-efficient installation in panelboards, switchboards, and motor control centers. UL 489 listed and CSA C22.2 No.5 certified, the JDL36250T meets IEC/EN 60947-2 international standards for global project specification and acceptance. Applications include feeder circuit protection, branch circuit protection, motor control center installations, panelboard and switchboard applications, and industrial power distribution systems requiring J-Frame frame-class protection capabilities. As part of the proven PowerPact family, the JDL36250T delivers dependable protection backed by Schneider Electric's extensive global engineering heritage and comprehensive industry-leading technical support resources.
Key Features
This PowerPact MCCB features Thermal-Magnetic (Field-Interchangeable) trip protection rated 250A at 600V AC / 250V DC. Frame size: 250A. Interrupting capacity: 25kA@240V, 18kA@480V, 14kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.
Applications
Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.