Square D PowerPact JDL36250TU53X J-Frame 3P 250A Field-Interch Electronic
250A Frame | 250A | 3P | 25kA@240V, 18kA@480V, 14kA@600V | Electronic Field-Interch (MicroLogic 5.2E LSI)
The Schneider Electric Square D PowerPact JDL36250TU53X is a J-Frame molded case circuit breaker rated at 250 amperes for 3-pole applications in commercial and industrial power distribution systems. This premium breaker delivers standard interrupting capacity rated at 25kA@240V, 18kA@480V, 14kA@600V, operating at 600V AC for reliable overcurrent protection in critical electrical infrastructure. The JDL36250TU53X features a MicroLogic 5.2E LSI electronic trip unit providing adjustable long-time delay, short-time delay, instantaneous, and ground fault protection settings for precise overcurrent coordination. This advanced electronic trip technology enables optimized protection curves, selective coordination with upstream and downstream protective devices, and significantly enhanced system reliability. Configured for unit mount installation, the JDL36250TU53X utilizes lug (unit mount) connections with AL250JD Lug terminations designed for reliable conductor termination. The unit accommodates 3/0-350 kcmil Al/Cu conductors within compact overall dimensions of 5.90" H x 4.50" W x 3.63" D weighing ~12 lbs, optimizing installation density in electrical distribution equipment. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the JDL36250TU53X carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 250A 3-pole overcurrent protection. The JDL36250TU53X exemplifies Schneider Electric's PowerPact platform engineering excellence, delivering consistent protection performance with robust construction designed for long service life in demanding environments.
Key Features
This PowerPact MCCB features Electronic Field-Interch (MicroLogic 5.2E LSI) trip protection rated 250A at 600V AC. Frame size: 250A. Interrupting capacity: 25kA@240V, 18kA@480V, 14kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.
Applications
Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.