Square D PowerPact JGA26250 J-Frame 2P 250A MCCB I-Line

star
star
star
star
star

250A, 2-Pole, MCCB, 600V, 65kA IC, J-Frame, TMD

Product Code:
In Stock
Available
Part Number
JGA26250
Manufacturer
Schneider Electric
Current Rating
250A
Voltage Rating (V)
600V AC / 250V DC
Number of Poles
2P
Weight
~11 lbs
Dimensions
9.70" H x 4.50" W x 5.17" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
250A
Rated Current
250A
Interrupting Capacity
65kA@240V, 35kA@480V, 18kA@600V
AIC Rating
18
Trip Type
Thermal-Magnetic (Adjustable)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
No
HACR Rated
Yes
Wire Range
3/0-350 kcmil Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: J-Frame 250A | IC: 65kA@240V, 35kA@480V, 18kA@600V | Poles: 2 | Voltage: 600V AC / 250V DC | Trip: Thermal-Magnetic (Adjustable) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Thermal-Magnetic (Adjustable)

Square D PowerPact JGA26250 J-Frame 2P 250A MCCB I-Line

250A Frame | 250A | 2P | 65kA@240V, 35kA@480V, 18kA@600V | Thermal-Magnetic (Adjustable)

Schneider Electric offers the Square D PowerPact JGA26250, a premium J-Frame 2-pole molded case circuit breaker delivering 250-ampere protection for critical electrical infrastructure and power distribution. With high interrupting capacity of 65kA@240V, 35kA@480V, 18kA@600V, this MCCB operates at 600V AC / 250V DC to provide comprehensive and dependable circuit protection. This breaker incorporates a factory-calibrated TMD (Thermal-Magnetic) trip unit providing both thermal overload and instantaneous magnetic short-circuit protection. The J-Frame platform's proven trip mechanism ensures reliable operation with consistent and repeatable protection characteristics for dependable circuit protection throughout the breaker's entire service life. The JGA26250 features i-line plug-on configuration with i-line plug-on connections and I-Line Bus Connection terminations for straightforward installation. Accepting 3/0-350 kcmil Al/Cu conductors, this breaker measures 9.70" H x 4.50" W x 5.17" D and weighs ~11 lbs, providing a compact footprint for space-efficient installation in panelboards, switchboards, and motor control centers. Certified to UL 489, CSA, and IEC/EN 60947-2 international standards, the JGA26250 ensures compliance across diverse global markets and jurisdictions. This breaker serves commercial and industrial power distribution, feeder protection, motor circuit applications, and switchgear installations requiring dependable J-Frame frame interrupting performance. The JGA26250 exemplifies Schneider Electric's PowerPact platform engineering excellence, delivering consistent protection performance with robust construction designed for long service life in demanding environments.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Adjustable) trip protection rated 250A at 600V AC / 250V DC. Frame size: 250A. Interrupting capacity: 65kA@240V, 35kA@480V, 18kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.