Square D PowerPact LLA34400WU43X L-Frame 3P 400A Mission Critical I-Line

star
star
star
star
star

400A, 3-Pole, MCCB, 277V, 125kA IC, L-Frame, MicroLogic 5.3A

Product Code:
In Stock
Available
Part Number
LLA34400WU43X
Manufacturer
Schneider Electric
Current Rating
400A
Voltage Rating (V)
480Y/277V AC
Number of Poles
3P
Weight
~30 lbs
Dimensions
15.24" H x 7.09" W x 8.07" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
600A
Rated Current
400A
Interrupting Capacity
125kA@240V, 100kA@480V, 50kA@600V
AIC Rating
50
Trip Type
Electronic Mission Critical (MicroLogic 5.3A LSI)
Trip Unit Model
MicroLogic 5.3A LSI
Mounting Style
I-Line Plug-On
Connection Type
I-Line Plug-On
Lug Configuration
I-Line Bus Connection
Current Limiting
Yes
Wire Range
(2) 3/0-500 kcmil Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: L-Frame 600A | IC: 125kA@240V, 100kA@480V, 50kA@600V | Poles: 3 | Voltage: 480Y/277V AC | Trip: Electronic Mission Critical (MicroLogic 5.3A LSI) | Mount: I-Line Plug-On | Connection: I-Line Plug-On
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Branch circuit protection, feeder protection, motor circuit protection, panelboard/switchboard applications, MCC installations
Special Features
Electronic Mission Critical (MicroLogic 5.3A LSI), Current Limiting

Square D PowerPact LLA34400WU43X L-Frame 3P 400A Mission Critical I-Line

600A Frame | 400A | 3P | 125kA@240V, 100kA@480V, 50kA@600V | Electronic Mission Critical (MicroLogic 5.3A LSI)

The Schneider Electric Square D PowerPact LLA34400WU43X is a L-Frame molded case circuit breaker rated at 400 amperes for 3-pole applications in commercial and industrial power distribution systems. This premium breaker delivers very high interrupting capacity rated at 125kA@240V, 100kA@480V, 50kA@600V, operating at 480Y/277V AC for reliable overcurrent protection in critical electrical infrastructure. The LLA34400WU43X features a MicroLogic 5.3A LSI electronic trip unit providing adjustable long-time delay, short-time delay, instantaneous, and ground fault protection settings for precise overcurrent coordination. This advanced electronic trip technology enables optimized protection curves, selective coordination with upstream and downstream protective devices, and significantly enhanced system reliability. Configured for i-line plug-on installation, the LLA34400WU43X utilizes i-line plug-on connections with I-Line Bus Connection terminations designed for reliable conductor termination. The unit accommodates (2) 3/0-500 kcmil Al/Cu conductors within compact overall dimensions of 15.24" H x 7.09" W x 8.07" D weighing ~30 lbs, optimizing installation density in electrical distribution equipment. Compliant with UL 489, CSA C22.2 No.5, and IEC/EN 60947-2 international standards, the LLA34400WU43X carries multiple certifications for worldwide acceptance and specification. Ideal for commercial buildings, industrial facilities, data centers, healthcare facilities, and critical infrastructure power distribution requiring reliable 400A 3-pole overcurrent protection. Backed by Schneider Electric's global expertise in power distribution solutions, the LLA34400WU43X ensures dependable protection for critical electrical infrastructure with comprehensive factory warranty coverage and support.

Key Features

This PowerPact MCCB features Electronic Mission Critical (MicroLogic 5.3A LSI) trip protection rated 400A at 480Y/277V AC. Frame size: 600A. Interrupting capacity: 125kA@240V, 100kA@480V, 50kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.