Square D PowerPact PLL34250CU74AE1 P-Frame 3P 250A MCCB Lug 100%

star
star
star
star
star

250A 3-Pole MCCB, 480V, 25kA, P-Frame, Micrologic 6.0H

Product Code:
In Stock
Available
Part Number
PLL34250CU74AE1
Manufacturer
Schneider Electric
Current Rating
250A
Voltage Rating (V)
480V AC
Number of Poles
3P
Weight
~18 lbs
Dimensions
10.04" H x 9.00" W x 5.79" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
1200A
Rated Current
250A
Interrupting Capacity
125kA@240V, 100kA@480V, 25kA@600V
AIC Rating
25
Trip Type
Electronic (MicroLogic 6.0H)
Trip Unit Model
MicroLogic 6.0H (LSIG) w/Modbus
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
AL1200CB Lug
Current Limiting
No
HACR Rated
Yes
Wire Range
1/0-500 kcmil Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: P-Frame 1200A | IC: 125kA@240V, 100kA@480V, 25kA@600V | Poles: 3 | Voltage: 480V AC | Amperage: 250A | Trip: MicroLogic 6.0H (LSIG) w/Modbus | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Industrial power distribution, Commercial building electrical systems, Motor control centers, Branch circuit protection, Feeder protection, Panelboard applications
Special Features
Electronic (MicroLogic 6.0H)

Square D PowerPact PLL34250CU74AE1 P-Frame 3P 250A MCCB Lug 100%

1200A Frame | 250A | 3P | 125kA@240V, 100kA@480V, 25kA@600V | Electronic (MicroLogic 6.0H)

Engineered for mission-critical electrical systems, the Square D PLL34250CU74AE1 P-Frame circuit breaker combines advanced trip technology with industrial-grade reliability. This 3-pole device is rated at 250A with 480V AC voltage capability and an interrupting capacity of 125kA@240V, 100kA@480V, 25kA@600V (Current-Limiting (L) interrupting class). It features a MicroLogic 6.0H advanced harmonic trip unit with LSIG protection, full harmonic analysis, power quality monitoring, and Modbus communication, rated at 80% continuous current per NEC Article 240.6. The PLL34250CU74AE1 is configured with AL1200CB Lug connections for reliable cable termination. This breaker is UL 489 listed and CSA certified with dual UL/IEC ratings, ensuring compliance across North American and international installations. With its combination of advanced protection features and robust construction, the PLL34250CU74AE1 is an excellent choice for demanding electrical distribution applications. The wire range accommodates 1/0-500 kcmil Al/Cu conductors for flexible installation options. This configuration is suitable for both new installations and retrofit applications in existing switchgear and panelboard assemblies. The PowerPact platform supports a comprehensive range of accessories for enhanced functionality, monitoring, and communication capabilities. Schneider Electric provides extensive technical documentation, CAD files, and application engineering support for proper selection and installation. All terminal connections are designed for easy installation and reliable long-term performance under continuous operating conditions.

Key Features

This PowerPact MCCB features Electronic (MicroLogic 6.0H) trip protection rated 250A at 480V AC. Frame size: 1200A. Interrupting capacity: 125kA@240V, 100kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.