Square D PowerPact QDA221002 Q-Frame 2P 100A MCCB I-Line 80% AC

star
star
star
star
star

100A, 2-Pole, MCCB, 240V, 25kA IC, Q-Frame, TMD

Product Code:
In Stock
Available
Part Number
QDA221002
Manufacturer
Schneider Electric
Current Rating
100A
Voltage Rating (V)
240V AC
Number of Poles
2P
Weight
~3 lbs
Dimensions
6.47" H x 3.00" W x 4.25" D
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
UL Listed
Yes
Frame Size
250A
Rated Current
100A
Interrupting Capacity
25kA@240Vac
AIC Rating
25
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
I-Line
Connection Type
I-Line Plug-In (AC)
Lug Configuration
I-Line Shroud
Current Limiting
No
HACR Rated
Yes
Wire Range
I-Line connection
Ambient Temperature
40°C
Technical Specifications
Frame: Q-Frame 250A | IC: 25kA@240Vac | Poles: 2 | Voltage: 240V AC | Amperage: 100A | Trip: TMD (Thermal-Magnetic) | Mount: I-Line | Connection: I-Line Plug-In (AC)
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
Application Use Case
Branch circuit protection, Feeder protection, Panelboard applications, Residential electrical panels, Commercial office distribution, Retail electrical systems, I-Line panelboard and switchboard installations
Special Features
Thermal-Magnetic (Fixed)

Square D PowerPact QDA221002 Q-Frame 2P 100A MCCB I-Line 80% AC

250A Frame | 100A | 2P | 25kA@240Vac | Thermal-Magnetic (Fixed)

The Square D PowerPact QDA221002 represents the Q-Frame series of compact 250A-class molded case circuit breakers, combining robust thermal-magnetic protection with versatile mounting options. This 2-pole device is rated at 100A with 240V AC voltage capability and an interrupting capacity of 25kA@240Vac. It features fixed thermal-magnetic trip elements in each pole, providing both overload (thermal) and short-circuit (magnetic) protection calibrated at 40 degrees Celsius ambient temperature, rated at 80% continuous current per NEC Article 240.6. The QDA221002 is featuring I-Line plug-in mounting for rapid installation and maintenance in Square D I-Line panelboards and switchboards. This device is UL 489 listed, CSA C22.2 No.5 certified, and NOM approved for use across North American installations, with an over-center toggle mechanism providing quick-make quick-break operation and trip-free functionality. Engineers and contractors rely on the QDA221002 for its proven track record of reliability, ease of installation, and comprehensive protection capabilities in low-voltage systems. The breaker operates reliably at ambient temperatures up to 40 degrees Celsius with correction factors available for higher temperature environments. Physical dimensions of 6.47" H x 3.00" W x 4.25" D with an approximate weight of ~3 lbs ensure compatibility with standard enclosures and panelboards. Field-installable accessories include handle padlock attachments (QBPA), service barriers (QSB2/QSB3), and mechanical interlock kits (QBMIK) for enhanced safety.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 100A at 240V AC. Frame size: 250A. Interrupting capacity: 25kA@240Vac. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1.