Square D PowerPact QDL22250 Q-Frame 2P 250A MCCB Lug 80%

star
star
star
star
star

250A, 2-Pole, MCCB, 240V, 25kA IC, Q-Frame, TMD

Product Code:
In Stock
Available
Part Number
QDL22250
Manufacturer
Schneider Electric
Current Rating
250A
Voltage Rating (V)
240V AC
Number of Poles
2P
Weight
~3 lbs
Dimensions
6.47" H x 3.00" W x 4.25" D
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
UL Listed
Yes
Frame Size
250A
Rated Current
250A
Interrupting Capacity
25kA@240Vac
AIC Rating
25
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
Box-Type Lug 4AWG-300kcmil
Current Limiting
No
HACR Rated
Yes
Wire Range
4 AWG-300 kcmil Cu only
Ambient Temperature
40°C
Technical Specifications
Frame: Q-Frame 250A | IC: 25kA@240Vac | Poles: 2 | Voltage: 240V AC | Amperage: 250A | Trip: TMD (Thermal-Magnetic) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
Application Use Case
Branch circuit protection, Feeder protection, Panelboard applications, Service entrance protection, Commercial building distribution, Light industrial applications
Special Features
Thermal-Magnetic (Fixed)

Square D PowerPact QDL22250 Q-Frame 2P 250A MCCB Lug 80%

250A Frame | 250A | 2P | 25kA@240Vac | Thermal-Magnetic (Fixed)

Schneider Electric's Square D QDL22250 PowerPact Q-Frame MCCB provides dependable thermal-magnetic overcurrent protection for commercial and residential electrical distribution. This 2-pole device is rated at 250A with 240V AC voltage capability and an interrupting capacity of 25kA@240Vac. It features fixed thermal-magnetic trip elements in each pole, providing both overload (thermal) and short-circuit (magnetic) protection calibrated at 40 degrees Celsius ambient temperature, rated at 80% continuous current per NEC Article 240.6. The QDL22250 is configured with box-type lug connections accommodating 4 AWG-300 kcmil Cu only conductors for reliable cable termination. This device is UL 489 listed, CSA C22.2 No.5 certified, and NOM approved for use across North American installations, with an over-center toggle mechanism providing quick-make quick-break operation and trip-free functionality. The QDL22250 represents Schneider Electric's commitment to safety and reliability in power distribution, backed by comprehensive technical support and worldwide parts availability. The device features a rated frequency of 50 to 60 Hz and an endurance rating of 1000 load cycles and 5000 no-load cycles for a total of 6000 operations. Schneider Electric provides extensive technical documentation, installation instructions, and trip curve data for proper application and coordination. The PowerPact Q-frame platform supports multiple termination options including lugs, studs, bus connections, and control wire taps for flexible installation. Field-installable accessories include handle padlock attachments (QBPA), service barriers (QSB2/QSB3), and mechanical interlock kits (QBMIK) for enhanced safety.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 250A at 240V AC. Frame size: 250A. Interrupting capacity: 25kA@240Vac. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1.