Square D PowerPact QJL32110 Q-Frame 3P 110A MCCB Lug 80%

star
star
star
star
star

110A, 3-Pole, MCCB, 240V, 100kA IC, Q-Frame, TMD

Product Code:
In Stock
Available
Part Number
QJL32110
Manufacturer
Schneider Electric
Current Rating
110A
Voltage Rating (V)
240V AC
Number of Poles
3P
Weight
~4 lbs
Dimensions
6.47" H x 4.50" W x 4.25" D
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
UL Listed
Yes
Frame Size
250A
Rated Current
110A
Interrupting Capacity
100kA@208Y/120Vac, 65kA@240Vac
AIC Rating
65
Trip Type
Thermal-Magnetic (Fixed)
Trip Unit Model
TMD (Thermal-Magnetic)
Mounting Style
Unit Mount
Connection Type
Lug (Unit Mount)
Lug Configuration
Box-Type Lug 4AWG-300kcmil
Current Limiting
No
HACR Rated
Yes
Wire Range
4 AWG-300 kcmil Al/Cu
Ambient Temperature
40°C
Technical Specifications
Frame: Q-Frame 250A | IC: 100kA@208Y/120Vac, 65kA@240Vac | Poles: 3 | Voltage: 240V AC | Amperage: 110A | Trip: TMD (Thermal-Magnetic) | Mount: Unit Mount | Connection: Lug (Unit Mount)
Standards Compliance
UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1
Application Use Case
Branch circuit protection, Feeder protection, Panelboard applications, Residential electrical panels, Commercial office distribution, Retail electrical systems
Special Features
Thermal-Magnetic (Fixed)

Square D PowerPact QJL32110 Q-Frame 3P 110A MCCB Lug 80%

250A Frame | 110A | 3P | 100kA@208Y/120Vac, 65kA@240Vac | Thermal-Magnetic (Fixed)

The Square D PowerPact QJL32110 represents the Q-Frame series of compact 250A-class molded case circuit breakers, combining robust thermal-magnetic protection with versatile mounting options. This 3-pole device is rated at 110A with 240V AC voltage capability and an interrupting capacity of 100kA@208Y/120Vac, 65kA@240Vac. It features fixed thermal-magnetic trip elements in each pole, providing both overload (thermal) and short-circuit (magnetic) protection calibrated at 40 degrees Celsius ambient temperature, rated at 80% continuous current per NEC Article 240.6. The QJL32110 is configured with box-type lug connections accommodating 4 AWG-300 kcmil Al/Cu conductors for reliable cable termination. This device is UL 489 listed, CSA C22.2 No.5 certified, and NOM approved for use across North American installations, with an over-center toggle mechanism providing quick-make quick-break operation and trip-free functionality. Engineers and contractors rely on the QJL32110 for its proven track record of reliability, ease of installation, and comprehensive protection capabilities in low-voltage systems. A visible trip indication mechanism with three handle positions (ON, tripped, and OFF) provides clear visual feedback of the breaker's operating status. The PowerPact Q-frame platform supports multiple termination options including lugs, studs, bus connections, and control wire taps for flexible installation. Field-installable accessories include handle padlock attachments (QBPA), service barriers (QSB2/QSB3), and mechanical interlock kits (QBMIK) for enhanced safety. The breaker operates reliably at ambient temperatures up to 40 degrees Celsius with correction factors available for higher temperature environments.

Key Features

This PowerPact MCCB features Thermal-Magnetic (Fixed) trip protection rated 110A at 240V AC. Frame size: 250A. Interrupting capacity: 100kA@208Y/120Vac, 65kA@240Vac. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5-02, NOM-003-SCFI, NEMA AB-1.