Square D PowerPact RJF46160CU31A R-Frame 4P 1600A MCCB 100%

star
star
star
star
star

1600A 4-Pole MCCB, 600V, 25kA, R-Frame, Micrologic 3.0

Product Code:
In Stock
Available
Part Number
RJF46160CU31A
Manufacturer
Schneider Electric
Current Rating
1600A
Voltage Rating (V)
600V AC
Number of Poles
4P
Weight
~55 lbs
Dimensions
14.88" H x 15.00" W x 7.00" D
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
UL Listed
Yes
Frame Size
3000A
Rated Current
1600A
Interrupting Capacity
100kA@240V, 65kA@480V, 25kA@600V
AIC Rating
25
Trip Type
Electronic (MicroLogic 3.0)
Trip Unit Model
MicroLogic 3.0 (LI)
Mounting Style
Unit Mount
Connection Type
No Lugs (Bus Connection)
Lug Configuration
Bus/RLTB Terminal Pad
Current Limiting
No
HACR Rated
No
Wire Range
Bus connection (RLTB kit)
Ambient Temperature
40°C
Technical Specifications
Frame: R-Frame 3000A | IC: 100kA@240V, 65kA@480V, 25kA@600V | Poles: 4 | Voltage: 600V AC | Amperage: 1600A | Trip: MicroLogic 3.0 (LI) | Mount: Unit Mount | Connection: No Lugs (Bus Connection)
Standards Compliance
UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE
Application Use Case
Industrial power distribution, Commercial building electrical systems, Motor control centers, Utility substations, Data center main distribution, Large manufacturing facilities
Special Features
Electronic (MicroLogic 3.0)

Square D PowerPact RJF46160CU31A R-Frame 4P 1600A MCCB 100%

3000A Frame | 1600A | 4P | 100kA@240V, 65kA@480V, 25kA@600V | Electronic (MicroLogic 3.0)

The Square D PowerPact RJF46160CU31A is a premium R-Frame MCCB designed by Schneider Electric for heavy industrial and utility-scale circuit protection. This 4-pole device is rated at 1600A with 600V AC voltage capability and an interrupting capacity of 100kA@240V, 65kA@480V, 25kA@600V (High (J) interrupting class). It features a MicroLogic 3.0 electronic trip unit providing long-time and instantaneous overcurrent protection (LI), rated at 80% continuous current per NEC Article 240.6. The RJF46160CU31A is equipped with busbar connection for direct mounting in power distribution switchgear. This breaker is UL 489 listed and CSA certified with dual UL/IEC ratings, ensuring compliance across North American and international installations. Engineers and contractors rely on the RJF46160CU31A for its proven track record of reliability, ease of installation, and comprehensive protection capabilities. The wire range accommodates Bus connection (RLTB kit) conductors for flexible installation options. Physical dimensions of 14.88" H x 15.00" W x 7.00" D with an approximate weight of ~55 lbs ensure compatibility with standard enclosures. The breaker operates reliably at ambient temperatures up to 40 degrees Celsius per UL and IEC standards. Field-installable accessories include shunt trip coils, undervoltage releases, auxiliary switches, alarm contacts, and motor operators for remote operation. The PowerPact platform supports a comprehensive range of accessories for enhanced functionality, monitoring, and communication capabilities.

Key Features

This PowerPact MCCB features Electronic (MicroLogic 3.0) trip protection rated 1600A at 600V AC. Frame size: 3000A. Interrupting capacity: 100kA@240V, 65kA@480V, 25kA@600V. Designed for reliable overcurrent protection in industrial and commercial power distribution systems.

Applications

Suitable for main distribution panels, motor control centers, switchboards, and feeder circuit protection in industrial facilities, data centers, and commercial buildings. Compliant with UL 489, CSA C22.2 No.5, IEC/EN 60947-2, NOM, CCC, CE.